Back to Learn
solar-fundamentals
equipment
system-design

How Solar Equipment Works Together

Panels, inverter, and batteries must be matched carefully. This guide explains how DC and AC interact, what MPPT tracking means, and what happens when components do not match.

SolMate Team26 February 20269 min read

A solar system is not a collection of independent gadgets. Your panels, inverter, and batteries are a team — and like any team, they only perform well when the members are matched to each other. Put a small inverter with too many panels and it clips your output. Pair a 24V battery with a 48V inverter and nothing works at all.

This guide explains how the three core components interact, what "matching" actually means, and how to avoid the expensive mistakes that come from buying equipment in isolation.

The Water Pipe Analogy

Before we get technical, think of your solar system like a water supply:

  • Panels are the reservoir on the hill — they create pressure (voltage) and flow (current)
  • The inverter is the pump house — it regulates the pressure and flow to match what your taps need
  • Batteries are the storage tank — they hold water for when the reservoir is empty (at night or during load shedding)
  • Your home's circuits are the taps — they draw water at a specific pressure (230V AC)

The pump house (inverter) can only handle water arriving within a certain pressure range. Too much pressure and the pipes burst. Too little and the pump cannot push water to the taps. The storage tank must operate at the same pressure as the pump house expects.

That is exactly how voltage matching works in a solar system.

How Panels Produce Power

Solar panels produce Direct Current (DC) — electricity that flows in one direction, like a battery. But the output is not fixed. It varies with:

  • Sunlight intensity — more sun means more current (amps)
  • Temperature — hotter panels produce less voltage (counterintuitive but true)
  • Time of day — output follows a bell curve from sunrise to sunset

A panel's nameplate rating (e.g., 550W) is measured under Standard Test Conditions: 1,000 W/sq m of sunlight and 25 degrees C cell temperature. In real Zimbabwe conditions — dust, heat, cloud — actual output is typically 85-92% of that rating.

Each panel has two key electrical properties:

PropertyWhat It MeansTypical Value (550W panel)
Voc (Open Circuit Voltage)Voltage with no load connected~49V
Isc (Short Circuit Current)Maximum current the panel can produce~14A
Vmp (Voltage at Max Power)Operating voltage at peak output~41V
Imp (Current at Max Power)Operating current at peak output~13.4A

How Panels Are Wired: Series and Parallel

You rarely connect a single panel to an inverter. Panels are grouped into strings, and how you wire them changes the electrical characteristics.

Series Wiring (Daisy Chain)

Connecting panels in series means the positive terminal of one panel connects to the negative terminal of the next. This adds voltages while current stays the same.

3 panels in series at 49V Voc each: 3 x 49 = 147V, current stays at ~14A

Parallel Wiring

Connecting panels in parallel means all positive terminals connect together and all negative terminals connect together. This adds currents while voltage stays the same.

3 panels in parallel at 14A Isc each: 3 x 14 = 42A, voltage stays at ~49V

Why This Matters

Most residential inverters have MPPT inputs that accept high voltage and moderate current. Series wiring is the default because it pushes voltage up into the inverter's tracking range without requiring excessively thick cables to handle high current.

Think of it this way: series wiring increases "pressure" (voltage), parallel wiring increases "flow" (current). Your inverter's MPPT input is designed for a specific pressure range. You build strings in series to hit that range.

The Inverter: System Brain

The inverter does three critical jobs:

  1. DC to AC conversion — your panels produce DC, your house runs on 230V AC
  2. MPPT tracking — continuously adjusting to extract maximum power from the panels as conditions change
  3. System management — deciding when to charge batteries, when to feed the grid, and when to switch sources during load shedding

The MPPT Voltage Window

MPPT stands for Maximum Power Point Tracking. The inverter's MPPT controller has a voltage window — a minimum and maximum voltage within which it can efficiently track and extract power.

Inverter SpecTypical Value (5kW hybrid)
Max DC Input Voltage500V (absolute limit — do not exceed)
MPPT Range120V - 430V (the efficient operating window)
Max Input Current per MPPT13A
Number of MPPT Trackers2

Your panel strings must produce a voltage that falls within the MPPT range under all conditions — hot afternoons (voltage drops) and cold mornings (voltage rises). If the string voltage falls below the MPPT minimum, the inverter cannot track efficiently and you lose output. If it exceeds the maximum DC input, you risk permanent damage.

The MPPT range and the maximum DC input voltage are different numbers. Your string voltage must stay within the MPPT range for efficient operation, and must never exceed the max DC input voltage under any conditions — including cold winter mornings when voltage is highest.

Batteries: Storing the Surplus

Batteries store excess solar energy for use when the panels are not producing — at night, during overcast weather, or during load shedding. In a hybrid system, they are the difference between "solar that helps during the day" and "solar that keeps the lights on all evening."

Voltage Matching

Batteries must match the inverter's DC bus voltage. This is non-negotiable.

System VoltageBattery ConfigurationCommon In
24VSingle 24V battery or 2 x 12V in seriesSmall systems under 3kW
48VSingle 48V battery or 4 x 12V in seriesStandard residential (3-8kW)
High-voltage (100-500V)Stacked battery modulesPremium systems (Pylontech, BYD)

If your inverter expects 48V DC from the battery, you cannot connect a 24V battery. It will either not work at all or damage the battery management system.

Capacity Sizing

Battery capacity (measured in kWh) determines how long you can run without solar or grid input. The calculation is straightforward:

Usable capacity = Total capacity x Depth of Discharge

A 5.12 kWh lithium battery with 90% depth of discharge gives you 4.6 kWh of usable energy. That runs a fridge, lights, Wi-Fi router, and TV for roughly 6-8 hours.

The DC/AC Ratio

The DC/AC ratio is the relationship between your total panel wattage (DC) and your inverter's AC output rating.

DC/AC Ratio = Total Panel Wattage / Inverter AC Rating

DC/AC RatioWhat It Means
Below 1.0Undersized panels — your inverter has spare capacity you are not using
1.0Perfectly matched — panels meet inverter capacity under ideal conditions
1.0 - 1.2Slightly oversized — recommended for Zimbabwe to account for real-world losses
1.2 - 1.3Moderately oversized — some clipping at midday, but better morning/afternoon output
Above 1.3Excessively oversized — significant energy wasted through clipping

In Zimbabwe, a DC/AC ratio of 1.1 to 1.2 is the practical recommendation. Your panels will rarely produce their full rated output due to temperature derating (panels get hot), dust soiling, and less-than-perfect orientation. Oversizing by 10-20% compensates for these real-world losses without wasting money.

Clipping is not dangerous — it just means the inverter limits its DC input to match its AC capacity, and the excess energy from your panels is not harvested. A small amount of clipping at midday is a reasonable trade-off for better output during the rest of the day.

What Happens When Components Do Not Match

MismatchWhat Happens
Panels too powerful for inverter (DC/AC ratio above 1.3)Inverter clips excess power. You paid for panel capacity you cannot use at peak.
String voltage too high (exceeds max DC input)Inverter input stage can be permanently damaged. The most expensive mistake.
String voltage too low (below MPPT minimum)Inverter cannot track efficiently. Erratic output, intermittent disconnections.
Battery voltage mismatch (e.g., 24V battery on 48V inverter)System will not charge or discharge. Can damage the battery's BMS.
Battery capacity too small for inverter powerHigh C-rates degrade lithium cells prematurely. The battery cycles too hard.

How to Check Compatibility

You can verify component matching manually by cross-referencing datasheets — or you can use the Match Builder tool in SolMate's Equipment section. It checks:

  • String voltage against inverter MPPT range (at both hot and cold temperatures)
  • Maximum DC input voltage (cold morning safety check)
  • DC current against inverter input limits
  • DC/AC power ratio
  • Battery voltage compatibility

Enter your chosen panels, inverter, and batteries, and the tool tells you whether the combination is safe and efficient — or where the mismatches are and how to fix them.

The Match Builder uses your location's temperature data to calculate voltage at real-world extremes, not just the standard 25 degrees C on the datasheet. A string that looks fine on paper can fail the cold-morning voltage check for Masvingo's winter lows.

Summary: The Matching Checklist

Before buying equipment, confirm these five things:

  1. Panel string voltage falls within the inverter's MPPT range at all temperatures
  2. Panel string voltage never exceeds the inverter's maximum DC input voltage (check at coldest temperature)
  3. DC/AC ratio is between 1.0 and 1.3 (aim for 1.1-1.2 in Zimbabwe)
  4. Battery voltage matches the inverter's DC bus voltage (48V system = 48V battery bank)
  5. Battery capacity is sufficient for the inverter's charge/discharge rate

Get these five right and your system will work as a team. Get any of them wrong and you are leaving performance on the table — or worse, risking equipment damage.

Equipment Lookup

Browse and compare certified solar equipment.